Skip to main navigation menu Skip to main content Skip to site footer

IMPLEMENTATION PRIORITIES FOR SAFER PEDIATRIC BRAIN CT IN NIGERIA: EVIDENCE SYNTHESIS FROM A SYSTEMATIC REVIEW AND LOCAL OPTIMIZATION STUDY

Abstract

Background: Pediatric brain computed tomography (CT) is a critical diagnostic tool in acute pediatric care, yet avoidable radiation exposure is a prominent patient-safety and public-health concern in low-resource environments. Because children possess high tissue radiosensitivity and a longer life expectancy, they face an elevated cumulative risk for radiation-induced malignancies, making dose optimization an ethical imperative. Aim: To synthesize global evidence from a systematic review with local empirical data from an optimization initiative to establish strategic implementation priorities for safer pediatric brain CT practice in Nigeria. Methods: This paper utilizes a contextual synthesis design linking a systematic review and a local quasi-experimental study. The systematic review component evaluated 12 high-quality quantitative studies extracted via a PRISMA-compliant search across PubMed, Web of Science, and Google Scholar. The local interventional component compared retrospective, pre-optimization baseline data ($158$ examinations) with prospectively collected post-optimization data (327 examinations) across selected hospitals in South-West Nigeria to analyze changes in Volumetric CT Dose Index {CTDI. vol} and Dose-Length Product {DLP}.  Results: The systematic review identified multiple effective optimization technologies worldwide, including automatic exposure control, age- or size-based technical parameter adjustments, and advanced reconstruction algorithms. Locally, the implementation of redesigned pediatric protocols yielded profound, statistically significant reductions (p < 0.001) in exposure. Mean {CTDI. vol} decreased by approximately 67%, dropping from 69.22 ± 0.78 to 23.13 ± 1.01{mGy}. Similarly, mean {DLP} fell by approximately 62%, decreasing from 1589.61 ± 0.74{mGy-cm} to $602.70 ± 1.02{ mGy-cm}. Conclusion: Substantial pediatric dose reduction can be achieved in everyday Nigerian clinical practice through structured protocol redesign, tighter scan coverage, and adjusted exposure parameters without requiring high-cost technologies. To sustain these improvements, pediatric radiation safety must be managed as a health-system quality and governance issue. Five core implementation priorities are recommended: establishing age- or size-specific protocols, developing local diagnostic reference levels, driving continuous workforce training, formalizing routine dose audits, and integrating pediatric safety into national quality policies. 

Keywords

Pediatric imaging, CT optimization, radiation safety, public health, Nigeria, implementation

PDF